Rheem Ruud Pressure Limit, Rollout Switches and Draft Inducers
Welcome to Our
Rheem Ruud Pressure Switches, Limit Switches, Rollout Switches and Draft
Inducers Page!
Same Business Day Shipping On All Orders Received Before 3 PM Eastern Standard Time!

We would Love to Have Your Business!
Our Website Page Links Directory below:
We Sell Heating, Air Conditioning Parts & Supplies To You At Low Wholesale Prices!
|
Hello Everyone! We Hope All of You Have A Happy, Healthful & Prosperous 2012!
We Hope You Will Find the Part your
furnace needs!
We ship UPS directly to your front door.
*We ship to the 50 United States. We do not ship to Canada.
Everything on this page is in stock and ready to ship.
You will receive a tracking number when we ship your order.
Dedicated to Fair Business Practices and Customer Satisfaction.
We are members of the Better Business Bureau with an A+ Rating.
Kentucky State Masters HVAC License # M01340



Shop With Confidence!
We are Square Trade & PayPal Verified Members!
We have VeriSign Secure Credit Card Processing and Cool Cart Secure Shopping Cart Service!
We Have Successfully Processed Over
8,500 PayPal Orders!
We Have Promptly Shipped Over
90,000 Orders Since 2002!
We are dedicated to helping you solve your heating & air conditioning problems!
Problem: Furnace
ignitor will not glow. If a furnace has a bad ignitor, open limit switch,
open rollout switch, open pressure switch or bad control board. This is what
I see in the furnace sequence of operation:
1. Thermostat calls for heat.
You should be getting 24 to 28 volts AC between the W (white) and C (com)
terminals on your control board.
*Make sure furnace safety switch is pressed in when testing.
2. Draft inducer motor starts.
If draft inducer does not start then you either have a thermostat problem,
thermostat wiring problem, transformer problem, bad relay on control board
or a draft inducer problem.
3. Pressure switch attached by a small plastic or rubber tube
to the draft inducer senses the negative pressure produced by the draft inducer and closes.
Should have 24 volts to ground across both terminals on the pressure switch.
If pressure switch is not closed with draft inducer running check for
stopped up vent or stopped up drain line on a condensing furnace.
4. Limit Switch and rollout switch/switches should all be closed.
Press in on the reset button in the center of each rollout switch to make sure
each rollout has been reset. You should have 24 to 28 volts from each terminal
to ground. On most furnaces the ignitor will not glow unless all the safety
controls (limit, rollout switch/switches, pressure switch) are closed. If a
limit or rollout switch is open then you might have an over heating problem and
a possible dangerous condition. If the Limit or rollout continues to trip I
would strongly recommend calling an HVAC service company to check your furnace
out.
5. Draft inducer runs for 30 seconds to a minute before you hear a gas hissing sound.
If you hear a hissing gas sound then more than likely either the ignitor is
broken or the relay on the control board that sends power to the ignitor is
broken. If the ignitor did not glow, the flame sensor (a small metal probe about 1/8" in diameter, with a white porcelain base) does not sense the flame, so after 8 to 10 seconds the hissing sounds stops with no ignition of gas to heat your home. Your furnace
will shut down, and try ignition again. Most of the time after three tries
the furnace will and go into a lock out condition until you turn your power switch back off and on again.
Solution:
You might need a new ignitor, rollout switch, limit switch, pressure
switch or control board.
Below we have pictures of the most popular Rheem, Ruud pressure switches, limits and rollout switches that many Rheem, Ruud furnaces have installed in them, with an opportunity for you to purchase.
Rheem, Ruud Limit Switch Part #47-25349-02-$20.00


This
47-25349-02 limit switch is used on the following models and replaces old limit
switch part numbers: 47-22679-02, 47-25351-02, 47-22695-02 and 47-22696-02
Rheem, Ruud Limit Switch Part #47-25349-03-$20.00


This
47-25349-03 limit switch is used on the following models listed below and
replaces old limit switch part numbers: 47-22679-03, 47-22696-03, 47-25351-03
and 47-22695-03.
Rheem, Ruud Manual Reset Rollout Limit Switch Part #47-22861-01

This Rheem, Ruud 47-22861-01
rollout limit switch is used on the following models:
Rheem, Ruud Manual Reset Rollout Limit Switch Part #47-22861-02

This Rheem, Ruud 47-22861-01
rollout limit switch is used on the following models:
Rheem Ruud Pressure Switch Section:
Rheem, Ruud Pressure Switch Part 42-24195-03

This Rheem, Ruud pressure switch
replaces pressure switch part numbers: 42-24012-02 and 42-24387-02.
This pressure switch kit is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Pressure Switch Kit Part 42-101233-81
This pressure switch kit replaces pressure switches 42-24335-02, 42-101233-01,
42-23648-02.

Rheem, Ruud Pressure Switch Kit Part 42-24196-81
This pressure switch kit replaces pressure switches: 42-101956-01, 42-24012-01,
42-24196-01,
42-24387-01.

Rheem, Ruud Pressure Switch Kit Part 42-24194-82
This pressure switch kit replaces pressure switches: 42-101233-02, 42-23648-03,
42-24064-01,
42-24194-02, 42-24335-03 and 42-22682-03. Pressure switch kit comes with
Pressure Switch Assembly, Wire & Cable Tie, Coupling (1/8" x 3/16" Plastic),
Silicone Rubber Tubing, Instruction Sheet and Wire Assembly.
This pressure switch kit is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Pressure Switch Kit Part 42-24196-82
This pressure switch kit replaces pressure switches: 42-101956-02, 42-24387-03,
42-24012-03 and
42-24196-02. Pressure switch kit comes with Pressure Switch
Assembly, Silicone Rubber Tubing, Instruction Sheet and Wire Assembly.
This pressure switch kit is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Pressure Switch Kit Part 42-24196-83
This pressure switch kit replaces pressure switches: 42-101956-03, 42-24196-03,
42-24387-04 and 42-24012-04. This pressure switch kit comes with Pressure Switch
Assembly, Silicone Rubber Tubing, Instruction Sheet and Wire Assembly.
This pressure switch kit is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Pressure Switch Kit Part 42-24196-84
This pressure switch kit replaces pressure switches: 42-101956-04, 42-24012-05,
42-24387-05 and
42-24196-04. This pressure switch kit comes with Pressure Switch
Assembly, Silicone Rubber Tubing, Instruction Sheet and Wire Assembly.
This pressure switch kit is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Draft Inducer Section:
Rheem, Ruud Draft Inducer Blower with Gasket Part
70-24033-01


Above picture of draft inducer and the back side of inducer showing gasket.
This draft inducer is used on the following furnace
models and replaces the following part numbers:
Rheem, Ruud Draft Inducer Blower with Gasket Part
70-24157-03

This draft inducer is used on the following furnace
models and replaces the following part numbers:
Did you find what you need? Below, you may use Google to search our site or the Web:
Thanks For the Opportunity to Do Business With You!
Privacy Statement: Please click here to see our Privacy Policy page if you are interested. Arnold's Service Company, Inc. is committed to protecting your privacy. Your personal information and email address will not be sold, rented or given to anyone. Your information will be used ONLY by Arnold's Service Company, Inc. We promise you!
To purchase using PayPal, Credit Card, Visa, MasterCard, Discover or American Express, just click on the "Add to Cart" button next to each item you would like to purchase. You will get an instant email "Notification of Purchase" when you finish your transaction.
PayPal It's Fast, Easy, Safe & Secure!
We Have VeriSign Secure Credit Card Processing!
We accept these credit cards:

We are Square Trade Members and PayPal Verified
Shop With Confidence!

Thanks for visiting Arnold's Service Company's Website!
Would you like to improve your website page ranking? Please click the link below for free Search Engine Optimization Tools.
Please visit our Favorite Christian Websites page. On this page we have a list of our Favorite Christian Websites. This page is intended to remind you of the eternal promises that are found in God's Holy Word and of God's never ending love for you. I try to read from some of these websites early each morning. It helps me get the day started out on the right track. I hope you enjoy these websites as much as I have!
God Bless you all.
Sincerely, Steve & Barbara Arnold
11506 Seatonville Road
Louisville, KY. 40291