Goodman Janitrol Furnace Ignitors
Welcome to Our Goodman, Janitrol Furnace Hot Surface Ignitors Page!
Same Business Day Shipping On All Orders Received Before 3 PM Eastern Standard Time!

We would Love to Have Your Business!
Our Website Page Links Directory below:
We Sell Heating, Air Conditioning Parts & Supplies To You At Low Wholesale Prices!
|
Hello Everyone! We Hope All of You Have A Happy, Healthful & Prosperous 2012!
We hope you can find the ignitor your furnace needs!
Be Prepared, Protect Your Family from being Uncomfortable and cold on those Cold Winter Nights.....Buy a spare furnace ignitor to have on hand. Since 1992, with the introduction of the new High efficiency furnaces, Ignitor failures on furnaces have become a major problem. I have seen it every year in my 16 year HVAC business. I do not want you to be caught out in the cold! That is why I am offering you these ignitors at wholesale prices!
Purchase your furnace ignitors from us and Save $$$$! We ship UPS directly to your front door.
*We ship to the 50 United States. We do not ship to Canada.
Everything on this page is in stock and ready to ship. We ship both UPS & USPS.

You will receive a tracking number when we ship your order.
Dedicated to Fair Business Practices and Customer Satisfaction.
We are members of the Better Business Bureau with an A+ Rating.
Kentucky State Masters HVAC License # M01340



We Have Successfully Processed Over
8,500 PayPal Orders!
We Have Promptly Shipped Over
90,000 Orders since 2002!
We are dedicated to helping you solve your heating & air conditioning problems!
Problem: Your furnace will not ignite the gas to produce heat for your home. When a furnace has a bad ignitor what I see most of the time is the following sequence of operation:
1. Thermostat calls for heat.
2. Draft inducer motor starts.
3. Pressure switch attached by a small plastic or rubber tube senses the negative pressure produced by the draft inducer and closes the circuit. Please make sure that you check your draft inducer to make sure the opening where the tube attaches from the pressure switch is open. I have seen many of these holes get stopped up so bad that you have to drill them out with a small drill bit. Take the tube off the pressure switch end. Blow into the tube. If you can not get any air through the tube then the draft inducer hole is stopped up. Drill it out with a small drill bit to repair this problem. If you have a 92% condensing furnace that produces water in the winter time, please check to make sure the drain lines are open. A stopped up drain line will cause the pressure switch not to close. Thus, the ignitor will not glow, if the pressure switch does not close. I use a wet vacuum many times to unstop the drains on condensing furnaces. Below we have some pictures of a draft inducer and pressure switches.

Above Goodman Janitrol Draft Inducer: Above Goodman Flame Sensor:

Above are pictures of two different types of pressure switches.
4. Draft inducer runs for 30 seconds to a minute before you hear a gas hissing sound. The ignitor did not glow, the flame sensor (a small metal probe about 1/8" in diameter, with a white porcelain base) does not sense the flame, so after 8 to 10 seconds the hissing sounds stops with no ignition of gas to heat your home. Your furnace shuts down and goes into a lock out condition until you turn your power switch back off and on again.
Solution: Sorry, but you need to purchase and install a new ignitor.
Below we have a picture of the Ignitor that many Janitrol furnaces have installed in them, with an opportunity for you to purchase.
Below is a scanned picture of various Ignitor Ceramic Block Styles & Terminal Block Styles. Hope this will help you match up your furnace with the correct ignitor. If you have a Janitrol or Goodman furnace, then the ignitor pictured below should be the ignitor you need to purchase for replacement. Thank You!
Goodman Janitrol Furnace Mini Hot Surface Ignitor Conversion Kit Part #0230K00001
This is the new Goodman, Janitrol Mini Hot Surface Ignitor Conversion Kit. This kit has been recommended to replace the standard carbide ignitors B1401015S and B1401018S used on previous Goodman, Janitrol furnaces. This mini ignitor conversion kit is not approved for the new GSU model furnaces. This ignitor is supposed to be more durable and longer lasting than the carbide ignitors, B1401015S and B1401018S. The kit comes with installation instructions, Mini Ignitor, Flat mounting plate, Screw and Adapter Harness. Below we have pictures with an opportunity for you to purchase.

Goodman Janitrol Furnace Hot Surface Ignitor Part #B1401018S
You might consider purchasing the 0230K00000S conversion kit that we sell above if you have the B1401018S, B1401015S ignitor and you do not have a GSU Goodman furnace.
This ignitor is an exact OEM replacement ignitor for Janitrol & Goodman furnaces. The part number is #B1401018S. This part number changed in 2003, and was a Part #B1401015S. The B1401018S ignitor also replaces Goodman Janitrol part #B140109S. If you have a Janitrol or Goodman furnace then we have the ignitor for you! Below is a picture of this Janitrol Goodman exact OEM replacement ignitor. This ignitor comes with a metal mounting bracket. It has a terminal connector "C." Please note that all the ignitors we sell are factory tested and have some burning, discoloration on the filament. Please click the "Add to Cart" button below to purchase. We appreciate your business! Please email us if you want us to look it up to make sure this ignitor fits your furnace before ordering. Our email address is: Support@arnoldservice.com

Above Goodman, Janitrol B1401018S, from left to right, Connector, Ignitor front view and Ignitor side view:
Goodman, Amana Furnace Hot Surface Ignitor Part #20165703S
This Goodman, Amana ignitor replaces part numbers: #20165703S, #20165703
201657-03, Model 601. This ignitor is made specifically for Goodman GMS & GKS furnaces. This ignitor replaces the ignitor in the Mini Igniter conversion kit Part #0230K00001 that we sell above. Below we have a picture of the ignitor with an opportunity for you to purchase. Please email us if you want us to look it up to make sure this ignitor fits your furnace before ordering. Our email address is: Support@arnoldservice.com

Goodman, Amana Furnace Hot Surface Ignitor Part #0130F00008S
This ignitor is used on many of the new model Goodman GMH series furnaces. Below we have pictures with an opportunity for you to purchase. Please email us if you want us to look it up to make sure this ignitor fits your furnace before ordering. Our email address is: Support@arnoldservice.com

Below are listed Links to Other Pages where we sell other specific Furnace Ignitors:
*For Your Information: When handling & installing ignitors never touch the gray glass part of the ignitor. Handle & install the ignitor using the white porcelin part of the ignitor. If you touch the gray glass, it could shorten the life of the ignitor. Ignitors are very fragile. If you drop it or hit it against something the ignitor will easily break.
Did you find what you need? Below, you may use Google to search our site or the Web:
Thanks For the Opportunity to Do Business With You!
Please read, some reasons why you should feel at ease when ordering from Arnold's Service Company, Inc.:
We Would Love to Have Your Business!
1. We Have Low Wholesale Prices on Heating & Air Conditioning Service,
Supplies and Parts! Some of the lowest prices found on the Internet!
2. We are dedicated to quick delivery of your parts and supplies with
quick UPS shipping right to your front door!
3. We give immediate Email confirmation after you purchase and
follow-up
4. We ship your order within 24 hours after you purchase.
5. We Email you an UPS tracking number the day we ship.
Privacy Statement: Please click here to see our Privacy Policy page if you are interested. Arnold's Service Company, Inc. is committed to protecting your privacy. Your personal information and email address will not be sold, rented or given to anyone. Your information will be used ONLY by Arnold's Service Company, Inc. We promise you!
To purchase using PayPal, Credit Card, Visa, MasterCard, Discover or American Express, just click on the "Add to Cart" button next to each item you would like to purchase. You will get an instant email "Notification of Purchase" when you finish your transaction.
PayPal It's Fast, Easy, Safe & Secure!
We Have VeriSign Secure Credit Card Processing!
We accept these credit cards:

We are Square Trade Members and PayPal Verified
Shop With Confidence!

Thanks for visiting Arnold's Service Company's Website!
Would you like to improve your website page ranking? Please click the link below for free Search Engine Optimization Tools.
God Bless you all.
Sincerely, Steve & Barbara Arnold
11506 Seatonville Road
Louisville, KY. 40291